An offshore oil rig has working production systems which normally produce around the clock and should not be shut down due to minor electrical faults. The use of ungrounded systems (floating systems) with appropriate monitoring devices from Bender ISOMETER® can guarantee this. Personal protection must also be ensured in the accommodation and supply units. This involves, for example, monitoring with RCMS residual current systems which allow the fastest possible warning and shutdown. All system data can be transferred to a central control point.
A Floating Production Storage and Offloading Unit (FPSO) is a ship used for extraction, storage and offloading of petroleum and natural gas. In offshore operations, FPSOs are used because they remove the need to construct a complicated, expensive pipeline infrastructure to the extraction site. Bender kits out these ships with the appropriate ISOMETER® technology to ensure maximum safety.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
EDS309x | Datasheets | 717.2 KB | EN | 2019/05/1313.05.2019 | D00012 |
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.3 MB | EN | 2024/10/2929.10.2024 | |
Earth fault protection of umbilicals | Flyer | 450.1 KB | EN | 2019/08/2828.08.2019 | |
Insulation Fault Location - Planning and Setup | Technical article | 112.4 KB | EN | 2019/05/1313.05.2019 | |
Electrical Safety in Control and Auxiliary Circuits | Technical article | 632.6 KB | EN | 2019/05/1313.05.2019 |
Products
Extension of the nominal voltage range of ISOMETER® iso685 series to AC 0...1150 V, DC 0...1760 V
Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V
Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V
Insulation monitoring device for inverter applications and large industrial plants
Insulation monitoring device for measuring high-resistance insulation resistances up to 10 GΩ and to monitor long parallel cable
The advanced Neutral Grounding Resistor Monitor for sophisticated applications
Portable insulation fault location systems for unearthed and earthed systems (IT and TN systems)
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Extension of the nominal voltage range of ISOMETER® iso685 series to AC 0...1150 V, DC 0...1760 V
Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V
Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V
Insulation monitoring device for inverter applications and large industrial plants
Insulation monitoring device for measuring high-resistance insulation resistances up to 10 GΩ and to monitor long parallel cable
The advanced Neutral Grounding Resistor Monitor for sophisticated applications
Portable insulation fault location systems for unearthed and earthed systems (IT and TN systems)
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
Electrical safety in low voltage distribution systems up to 1000 V ac and 1500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
Mobile and fixed offshore units - Electrical installations - Part 1: General requirements and conditions
Mobile and fixed offshore units - Electrical installations - Part 2: System design
Mobile and fixed offshore units - Electrical installations - Part 5: Mobile units
Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas